Emergency Power Plant
Emergency Power Plant
Emergency Power Plant
Emergency Power Plant
Emergency Power Plant
Emergency Power Plant
Emergency Power Plant
Emergency Power Plant
Emergency Power Plant

Emergency Power Plant

Model NO.:
Emergency Power Plant
Delivery:
FOB
Our company has many brands of diesel generator sets, with complete power, suitable for various places. In order to meet user needs, various customizations are supported. Regarding the choice of generator, we provide professional advice and product introduction.
Quantity:

Product description:

The emergency power station consists of a four-wheel trailer and a diesel engine. The design is scientific and practical. The emergency power station can be moved and is very convenient to use. Whether it is engineering construction or on-site construction, it has been affirmed by users. We have guaranteed quality and safety, and our engine brand has many choices. Customer satisfaction is our biggest motivation. The emergency generator set is mainly used in important places, cut off the power immediately after an emergency or unexpected power failure. The emergency generator set can quickly recover and extend the power supply time. Therefore, the generator set plays an important role in industrial applications, large electric power public places, etc. It is particularly important to choose a generator set with good quality and stability.

Beidou power generator advantages:

1. Due to the silent enclosure, the noise of the emergency generator is very low.

2. Design and manufacture in strict accordance with national standards.

3. Adjustable plug-in tractor, suitable for tractors of various heights.

4. Optional accessories.

5. The alternator is stable, runs smoothly, and can automatically adjust the voltage.

6. The generator set has the characteristics of low fuel consumption, low emissions, low noise and compact structure.

7. We will be responsible for the maintenance of all failures caused by the failure of the generator set according to the original factory regulations.

8. High reliability, using domestic and foreign well-known engines and supporting equipment to ensure reliability in harsh environments, meet the performance requirements of generators, integrated design, reliable structure, the company is committed to the pursuit of product quality, leading manufacturing technology Is to ensure high-quality products.

9. Large capacity fuel tank.

10. Equipped with a quick-open cover, easy to maintain.

Mobile silent generator set delivered to customer:

Product  Parameter:

We have several kinds of power for you to choose. Please see what products we have. I believe there will always one for you.

MODEL

POWER

DIMENSIONSmm)

WEIGHTKG)

VOLTAGE(V)

FREQUENCY(HZ)

KW

KVA

YUCHAI

BD-Y30

30

37.5

2400*1700*2400

1650

400/230

50

BD-Y40

40

50

2400*1700*2400

1700

400/230

50

BD-Y50

50

62.5

2400*1700*2400

1750

400/230

50

BD-Y64

64

80

2400*1700*2400

1800

400/230

50

BD-Y80

80

100

3000*1900*2600

2350

400/230

50

BD-Y100

100

125

3000*1900*2600

2500

400/230

50

BD-Y120

120

150

3200*1900*2600

2800

400/230

50

BD-Y150

150

187.5

3300*2100*2700

3200

400/230

50

BD-Y160

160

200

3300*2100*2700

3300

400/230

50

BD-Y200

200

250

3700*2100*2900

4200

400/230

50

BD-Y250

250

312.5

3700*2100*3100

4400

400/230

50

BD-Y300

300

375

4000*2100*3000

5300

400/230

50

BD-Y350

350

437.5

4200*2100*3150

6400

400/230

50

BD-Y400

400

500

4300*2250*3150

6900

400/230

50

BD-Y450

450

562.5

4300*2250*3150

8300

400/230

50

BD-Y500

500

625

4900*2250*3400

9300

400/230

50

Can be customized according to user requirements.

Some notes about the use of Beidou diesel generators:
1. Preparation before starting. Before each start, you must check whether the cooling water or antifreeze in the diesel water tank meets the requirements. If it is missing, fill it. Pull out the oil gauge and check for lack of lubricant. If it is missing, add it to the desired"quiet full scale", and then carefully check the related components for potential hidden dangers. If any fault is found, it should be cleared in time to start.

2. It is strictly prohibited to start the diesel engine under load. Before starting the diesel engine, please note that the output air switch of the generator must be off. After starting the diesel engine of the ordinary generator set, it needs to run at idle speed (about 700 rpm) for 3-5 minutes. In winter, when the temperature is low, the idle speed should be extended for a few minutes. After the diesel engine is started, you must first observe whether the oil pressure is normal and whether there are abnormal conditions such as oil leakage and water leakage. (Under normal circumstances, the oil pressure must be higher than 0.2MPa). If abnormality is found, stop the machine immediately for maintenance. If there is no abnormal phenomenon to increase the speed of the diesel engine to the rated speed of 1500 rpm, at this time the generator shows a frequency of 50HZ and a voltage of 400V, you can turn off the output air switch and put it into use. The generator set is not allowed to run without load for a long time. (Because long-term no-load operation will cause the diesel fuel injected by the diesel injector to not fully burn and cause carbon deposits, resulting in leakage of valves and piston rings.) If it is an automatic generator, it is not necessary because the automatic device is usually equipped with a water heater. When idling, the cylinder of the diesel engine is always maintained at around 45 ° C. After the diesel engine is started, it can usually transmit power within 8 to 15 seconds.

3. Pay attention to working status during operation. In the work of the generator set, there must be a person on duty, and often pay attention to observe a series of possible failures, especially pay attention to important factors such as changes in oil pressure, water temperature, oil temperature, voltage, frequency, etc. In addition, we should also pay attention to have enough diesel. If the fuel is interrupted during operation, it will objectively cause the load to stop, which may damage the generator excitation control system and related components.

4.Parking with load is strictly prohibited. Before each stop, the load must be cut off gradually, and then the output air switch of the generator set is turned off. Finally, before stopping, the diesel engine should be decelerated to idle and run for about 3-5 minutes.

For detailed mobile silent generator technology and inquiries, please contact our sales manager.

Send Message

*
*

Related Products

Model NO.: Trailer Type Generator
Model NO.: Movable Perkins Engine Generator
Model NO.: 100KVA Diesel Generator on Trailer
Model NO.: 30 KW Movable Generator

Send Message

*
*
Choose language