Detailed introduction:
About Beidou's Large Factory Generator:
Beidou's diesel generator set is a kind of power generation equipment that uses diesel as the main fuel. The diesel engine is used as the motive power to drive the generator to generate electricity and convert kinetic energy into electrical energy and thermal energy.The complete diesel generator set of Beidou
Power is mainly divided into three parts: diesel engine/generator/controller.The Beidou diesel generator set can be widely used in mining, railway, field construction, road traffic maintenance, and factories, enterprises, hospitals and other departments.This article mainly introduces the application of high-power diesel generator set in the factory.
Beidou's Large Factory Generator advantages:
1. Wide range of use, fuel economy, high thermal efficiency
3. Reliable, durable and low failure
4. Lower harmful emissions, reduce pollution
5. Good fire safety and low maintenance cost
6. Equipment support customization, container unit, mobile energy vehicle
Wait a minute, Beidou Power Equipment Co., Ltd. guarantees the use of brand new genuine diesel generator sets.
Basic parameters of Large Factory Generator unit (≥1000KW-open-fram-type)
Model | Output (KW/KVA) | Diesel engine | Cylinders | Displacement (L) | Dimensions/L×W×H (mm) | Weight (KG) |
BD-Y1000 | 1000/1250 | YC12VC1680L-D20 | 12 | 79.17 | 6500*2300*2600 | 13350 |
BD-Y1200 | 1200/1500 | YC12VC2070L-D20 | 12 | 79.17 | 6500*2300*2600 | 13350 |
BD-Y1320 | 1320/1650 | YC12VC2270L-D20 | 12 | 79.17 | 6500*2300*2600 | 13350 |
BD-Y1500 | 1500/1875 | YC12VC2510L-D20 | 12 | 79.17 | 6500*2300*2600 | 13350 |
BD-C1000 | 1000/1250 | KTA50-G3 | 16 | 50 | 5120*2040*2640 | 9210 |
BD-C1120 | 11201400 | KTA50-G8 | 16 | 50 | 5120*2040*2700 | 9570 |
BD-C1200 | 1200/1500 | KTA50-GS8 | 16 | 50 | 5120*2040*2700 | 9570 |
BD-P1000 | 1000/1250 | 4012-46TWG2A | 12 | 45.8 | 4920*1900*2420 | 9059 |
BD-P1200 | 1200/1500 | 4012-46TAG2A | 12 | 45.8 | 5100*1900*2440 | 9720 |
BD-P1368 | 1368/1710 | 4012-46TAG3A | 12 | 45.8 | 5220*2210*2490 | 10890 |
BD-P1480 | 1480/1850 | 4016-61TRG1 | 16 | 61.1 | 5730*2300*3020 | 15500 |
BD-P1480 | 1480/1850 | 4016TAG1A | 16 | 61.1 | 5730*2300*3020 | 15500 |
BD-P1600 | 1600/2000 | 4016TAG2A | 16 | 61.1 | 5730*2300*3020 | 15500 |
BD-P1600 | 1600/2000 | 4016-61TRG2 | 16 | 61.1 | 5730*2300*3020 | 15500 |
BD-P1800 | 1800/2250 | 4016-61TRG3 | 16 | 61.1 | 5730*2300*3020 | 15500 |
BD-W1000 | 1000/1250 | 12M33D1210E200 | 12 | 39.2 | 4200*1500*2200 | 10000 |
The basic types of generator sets produced by our company:
The types of generator sets that Beidou Power can provide are:
1.Open frame generator set
2.Silent generator set
3.Rainproof generator set
4.Mobile rainproof generator set
5.Mobile silent generator set
6.Automatic unit series
The brands of generator sets larger than 1000kw in Beidou Power include Yuchai, Cummins, Perkins, Weichai and so on. If the diesel generator set is used as a factory backup, the equipment in the plant is basically ordinary equipment, such as: fire pumps, welding machines, lighting, air compressors, cutting machines, etc., the performance requirements of the diesel engine are not high. However, for high-power units, we still recommend that customers use high-quality units and use higher-level automation controllers or ATS, etc.
1200KW YUCHAI OF LARGE FACTORY GENERATOR MADE BY BEIDOU POWER:

What are the points of attention of Beidou Power regarding the engine room of the diesel generator set of the factory?
The generator set used in the factory should normally be set up with a separate oil storage room. The oil storage capacity does not exceed the required amount of 8 hours. Take measures to prevent leakage and oil leakage. The oil tank should be ventilated (outdoor). The oil storage room should be separated from the generator and the firewall Open; when the party must open the door on the firewall, it should set up a class A fire door that can be closed by itself, set up a fire alarm device, and set up fire extinguishing facilities: such as gas, foam, water spray and other automatic fire extinguishing facilities (extinguish oil fires).
When choosing the location of the equipment room, pay attention to the following points: ① try to be as close to the substation as possible, which is convenient for wiring, shortening the length of the cable, and reducing power consumption. ② When it is installed in the first floor underground, try to have a side against the outer wall to facilitate ventilation and smoke exhaust. ③ It should be noted that the lifting, handling and maintenance of the unit are convenient. Generally, the parking garage access channel is used as a transportation channel, but if the channel cannot meet the requirements, it should be considered to reserve lifting holes.
The configuration of the fire protection implementation in the plant room:
Dry powder fire extinguishers and gas fire extinguishers must be installed in the engine room.Fire hydrants, fire hoses and fire hoses are installed outside the machine room.And set up eye-catching prohibited fireworks icons and prohibited fireworks text around the machine room.Dry fire sand is set inside the machine room.There must be isolation facilities from the oil room.The generator set should be at least 1 meter away from buildings and other equipment, and ice should be well ventilated.There are emergency lighting and emergency instructions inside the machine room. If it is a basement, there is an independent exhaust system and fire alarm device.
Contact us:
For more brands and factories, the units used in different places can contact our sales staff, we will recommend the right products and prices to you within the first time, click here to consult directly.